Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Clin Chem Lab Med ; 2022 Oct 26.
Article in English | MEDLINE | ID: covidwho-2227164

ABSTRACT

OBJECTIVES: The rapid, accurate and safe detection of SARS-CoV-2 is the key to improving surveillance and infection containment. The aim of the present study was to ascertain whether, after heat/chemical inactivation, SARS-CoV-2 N antigen chemiluminescence (CLEIA) assay in saliva remains a valid alternative to molecular testing. METHODS: In 2022, 139 COVID-19 inpatients and 467 healthcare workers were enrolled. In 606 self-collected saliva samples (Salivette), SARS-CoV-2 was detected by molecular (TaqPath rRT-PCR) and chemiluminescent Ag assays (Lumipulse G). The effect of sample pre-treatment (extraction solution-ES or heating) on antigen recovery was verified. RESULTS: Salivary SARS-CoV-2 antigen assay was highly accurate (AUC=0.959, 95% CI: 0.943-0.974), with 90% sensitivity and 92% specificity. Of the 254 antigen positive samples, 29 were false positives. We demonstrated that heterophilic antibodies could be a cause of false positive results. A significant antigen concentration decrease was observed after ES treatment (p=0.0026), with misclassification of 43 samples. Heat had a minimal impact, after treatment the correct classification of cases was maintained. CONCLUSIONS: CLEIA SARS-CoV-2 salivary antigen provides accurate, timely and high-throughput results that remain accurate also after heat inactivation, thus ensuring a safer work environment. This supports the use of salivary antigen detection by CLEIA in surveillance programs.

2.
BMC Med ; 20(1): 96, 2022 02 23.
Article in English | MEDLINE | ID: covidwho-1708803

ABSTRACT

BACKGROUND: The active surveillance of students is proposed as an effective strategy to contain SARS-CoV-2 spread and prevent schools' closure. Saliva for molecular testing is as sensitive as naso-pharyngeal swab (NPS), self-collected and well accepted by participants. This prospective study aimed to verify whether the active surveillance of the Padua University employees by molecular testing of self-collected saliva is an effective and affordable strategy for limiting SARS-CoV-2 spread. METHODS: A surveillance program based on self-collection of saliva every 2 weeks (October 2020-June 2021) was conducted. Among 8183 employees of the Padua University, a total of 6284 subjects voluntarily took part in the program. Eight collection points guaranteed the daily distribution and collection of barcoded salivary collection devices, which were delivered to the laboratory by a transport service for molecular testing. Quarantine of positive cases and contact tracing were promptly activated. RESULTS: Among 6284 subjects, 206 individuals were SARS-CoV-2 positive (99 by salivary testing; 107 by NPS performed for contact tracing or symptoms). The cumulative SARS-CoV-2 incidence in this cohort was 3.1%, significantly lower than that of employees not in surveillance (8.0%), in Padua (7.1%) and in the Veneto region (7.2%). Employees with positive saliva results were asymptomatic or had mild symptoms. The levels of serum antibodies after 3 months from the infection were correlated with age and Ct values, being higher in older subjects with greater viral loads. CONCLUSIONS: Salivary-based surveillance with contact tracing effectively allowed to limit SARS-CoV-2 contagion, also in a population with a high incidence.


Subject(s)
COVID-19 , SARS-CoV-2 , Aged , Humans , Pandemics , Prospective Studies , Saliva
3.
Clin Chim Acta ; 517: 54-59, 2021 Jun.
Article in English | MEDLINE | ID: covidwho-1091904

ABSTRACT

BACKGROUND AND AIM: SARS-CoV-2 quick testing is relevant for the containment of new pandemic waves. Antigen testing in self-collected saliva might be useful. We compared salivary and naso-pharyngeal swab (NPS) SARS-CoV-2 antigen detection by a rapid chemiluminescent assay (CLEIA) and two different point-of-care (POC) immunochromatographic assays, with results of molecular testing. METHODS: 234 patients were prospectively enrolled. Paired self-collected saliva (Salivette) and NPS were obtained to perform rRT-PCR, chemiluminescent (Lumipulse G) and POC (NPS: Fujirebio and Abbott; saliva: Fujirebio) for SARS-CoV-2 antigen detection. RESULTS: The overall agreement between NPS and saliva rRT-PCR was 78.7%, reaching 91.7% at the first week from symptoms. SARS-CoV-2 CLEIA antigen was highly accurate in distinguishing positive and negative NPS (ROC-AUC = 0.939, 95%CI:0.903-0.977), with 81.6% sensitivity and 93.8% specificity. This assay on saliva reached the optimal value within 7 days from symptoms onset (Sensitivity: 72%; Specificity: 97%). Saliva POC antigen was limited in sensitivity (13%), performing better in NPS (Sensitivity: 48% and 66%; Specificity: 100% and 99% for Espline and Abbott respectively), depending on viral loads. CONCLUSIONS: Self-collected saliva is a valid alternative to NPS for SARS-CoV-2 detection by molecular, but also by CLEIA antigen testing, which is therefore potentially useful for large scale screening.


Subject(s)
Antigens, Viral/analysis , COVID-19/diagnosis , Saliva/chemistry , Humans , Luminescent Measurements , Nasopharynx/virology , Pandemics , Point-of-Care Testing , Prospective Studies , SARS-CoV-2 , Sensitivity and Specificity
4.
Clin Chem Lab Med ; 58(9): 1579-1586, 2020 08 27.
Article in English | MEDLINE | ID: covidwho-612047

ABSTRACT

Objectives: The direct identification of SARS-CoV-2 RNA in nasopharyngeal swabs is recommended for diagnosing the novel COVID-19 disease. Pre-analytical determinants, such as sampling procedures, time and temperature storage conditions, might impact on the end result. Our aim was to evaluate the effects of sampling procedures, time and temperature of the primary nasopharyngeal swabs storage on real-time reverse-transcription polymerase chain reaction (rRT-PCR) results. Methods: Each nasopharyngeal swab obtained from 10 hospitalized patients for COVID-19 was subdivided in 15 aliquots: five were kept at room temperature; five were refrigerated (+4 °C); five were immediately mixed with the extraction buffer and refrigerated at +4 °C. Every day and for 5 days, one aliquot per condition was analyzed (rRT-PCR) for SARS-CoV-2 gene E and RNaseP and threshold cycles (Ct) compared. To evaluate manual sampling, 70 nasopharyngeal swabs were sampled twice by two different operators and analyzed separately one from the other. Results: A total of 6/10 swabs were SARS-CoV-2 positive. No significant time or storage-dependent variations were observed in SARS-CoV-2 Ct. Re-sampling of swabs with SARS-CoV-2 Ct lower than 33 resulted in highly reproducible results (CV=2.9%), while a high variability was observed when Ct values were higher than 33 (CV=10.3%). Conclusions: This study demonstrates that time and temperature of nasopharyngeal swabs storage do not significantly impact on results reproducibility. However, swabs sampling is a critical step, and especially in case of low viral load, might be a potential source of diagnostic errors.


Subject(s)
Betacoronavirus/chemistry , Nasopharynx/virology , RNA, Viral/analysis , Specimen Handling/methods , Aged , Aged, 80 and over , COVID-19 , COVID-19 Testing , Clinical Laboratory Techniques , Coronavirus Envelope Proteins , Coronavirus Infections/diagnosis , Diagnostic Tests, Routine , Female , Humans , Male , Middle Aged , Pandemics , Pneumonia, Viral/diagnosis , Reproducibility of Results , Reverse Transcriptase Polymerase Chain Reaction , Ribonuclease P/genetics , SARS-CoV-2 , Temperature , Time Factors , Viral Envelope Proteins/genetics
SELECTION OF CITATIONS
SEARCH DETAIL